With the introduction of said CFAMS system any fire alarms in unmanned substations within the Tubli WPCC will be monitored and communicated by the STP control room and security gate personnel to the Fire department and concern staff immediately
The Fire alarm monitoring system at Tubli Water Treatment Plant for detecting and notifying fire alarms at Substations would be integrated via LPUs using existing SCADA FOC Fiber Optic Communication ring
The alarm notifications and beef sounds will be displayed on two Repeater panels located in STP control room and Security Room accordingly
The Fire Alarm Panel signal will be connected to a Modbus Gateway module Moxa ioLogik for interfacing with the existing communication channels and the FAMS at HYBACS substations will be incorporated into the SCADA using FlexEdge module
,
1. يهدف مشروع نظام إنذار الحريق المركزي لتوصيل و ربط و مراقبة أجهزة الإنذار و مكافحة الحريق الموجودة في محطات الكهرباء الفرعية و المرفقات الأخرى في مركز توبلي لمعالجة مياه الصرف الصحي بكل من غرفة التشغيل و التحكم الرئيسية في المركز غرفة الأمن الدفاع المدني و الجهات الأخرى ذات العلاقة بشكل مباشر سيتم عمل التوصيل الخاص بنظام الحريق المركزي المطلوب من خلال شبكة خطوط الألياف الضوئية و ألواح الإتصال الموجودة في مركز توبلي و الخاصة بنظام التحكم و التشغيل SCADA بحيث سيتم نسخ و عكس لوحات التحكم في نظام الحريق في الأماكن المذكورة المراد ربطها بأجهزة الحريق في المواقع